Quality control interview Questions:



Q1. What is room temperature?
Ans) 25 degree centigrade
Q2.  What is the Ultraviolet(UV) and visible spectroscopy range?
Ans) UV spectroscopy range 200-400 nm, Visible spectroscopy range 400 nm to 800nm.
Q3) What is the use of UV Spectroscopy?
Ans) Spectroscopy used for detecting the functional groups, impurities. Qualitative and quantitative analysis can be done.
Q4) What is the difference between qualitative and quantitative analysis?
Ans) Qualitative analysis involves identification of the compound or chemical based on their chemical(absorption, emission )or physical properties(e.g Melting point, boiling point).
Quantitative analysis involves estimation or determination of concentration or amount of the chemical compounds or components.
Q5) Explain the principle of Ultraviolet spectroscopy?
Ans) UV spectroscopy uses light in the UV part of electromagnetic spectrum. UV absorption spectra arises in which molecule or atoms outer electrons absorb energy, undergoes transition from lower energy level to higher energy level. For each molecule, absorbance at wavelength is specific.
Q6) Explain about Beer Lamberts law?
Ans) It states that the intensity of monochromatic light absorbed by a substance dissolved in a fully transmitting solvent is directly proportional to the substance concentration and the path length of the light through the solution.
Q7)  Explain the Infrared spectroscopy principle?
Ans) When a molecule absorbs the Infrared radiation, it vibrates and gives rise to packed Infrared(IR) absorption spectrum. This IR spectrum is specific for every different molecule absorbing the IR radiation, useful for its  identification.
Q8) What is the body temperature?
Ans) 37 oCelsius or 98.6 oF

Q9) Define pH? What is the pH of blood?

Ans) pH -Negative logarithm of hydrogen ion concentration. Blood pH-7.35 to 7.45.
Q10) Expand LCMS, HPLC,UPLC, TLC and GC?
Ans) LCMS- Liquid Chromatography
HPLC- High Performance Liquid Chromatography,
UPLC- Ultra High Performance Liquid Chomatography,
TLC- Thin Layer Chomatography,
GC- Gas Chromatography

Q11) What is the HPLC principle?
Ans) It is a technique used for separating the mixture of components into individual components based on adsorption, partition, ion exchange and size exclusion principles. Stationary phase and mobile phase used in it.  HPLC used for identification, quantification and purification of components form a mixture.
Q12) Explain HPLC instrumentation?
Ans) It involves solvent system, pump, Sample injector, HPLC columns, Detectors and Recorder. Firstly, solvent(mobile phase) is degassed for eliminating the bubbles. It is passed through the pump with a uniform pressure. The liquid sample is injected into the mobile phase flow stream. It passes through the stationary phase identified by the detectors and recorded.
Q13) In reverse phase HPLC, which type of stationary phase is used and give example?
Ans) Non polar stationary phase used
Ex: Silica gel C-18
Q14) What are the detectors used in HPLC?
Ans) UV detector, IR detector, Fluorescence detector, Mass spectroscopy, LC MS etc.

Q15) How to calculate Retention factor in paper chromatography?

Ans) Rf = Distance travelled by solute/ Distance travelled by solvent.
Q16) Define molarity?
Ans) Number of moles of solute per litre solution. Denoted with “M”
Q17) Define Molality?
Ans) Number of moles of solute per kilogram solvent. Denoted with “m”
Q18) Define Normality?
Ans) Number of Number of moles equivalent per litre solution.
Q19) Molecular weight of oxygen?
Ans) 16
Q20)  Difference between humidity and relative humidity?
Ans) Humidity – Measure of amount of water vapour present in the atmosphere.
Relative humidity- Water vapour amount exists in air expressed as a percentage of the amount needed for saturation at the same temperature.




Acceptance Limit for Friability of tablets?

Ans) Acceptable tablets weight loss is 0.5 to 1.0% for 100 revolutions. Or 1-5% weight loss for 10 minutes revolution. ( Generally 6 grams of weighed and de dusted tablets place in the rotating apparatus, it revolves at a speed of 25 revolutions per minute i.e 25 rpm. Tablets freely falls from 6 inch height for every rotation. These tablets subjected to 100 rotations or for 10 minutes i.e 250 rotations (10 min*25rpm)).
Acceptance limit for uniformity of content of tablets?

Ans) There are two criterias for acceptance limit.
Take 30 randomly selected tablets. Take 10 tablets, and assay individually. 9 out of 10 tablets should be in the range of 85% to 115%. One tablet can be in the range of 75%-125%. If this criteria fits, it passes the test. If these conditions not met, remaining 20 tablets should be assayed. All of the 20 tablets should in the range of 85% to 115%.

What are different types of capsule sizes and holding capacity of smallest and largest size?

Ans) Sizes are 000, 00 , 0, 1, 2, 3, 4, 5.
Smallest size 5, It can hold at least 65 mg of drug.
Largest size 000, It can hold up to 1000 mg of drug.
What are the types of Gas Chromatography?
Ans) Two types available.
Gas Solid chromatography(GSC) : Stationary phase is solid and gas used as mobile phase.
Gas Liquid chromatography(GLC): Liquid on a thin solid support used as stationary phase and gas used as mobile phase.

Which material used as stationary phase and mobile phase in GSC and GLC ?

Ans) Granular silica, alumina or carbon used as stationary in phase in GSC. Non volatile liquid on solid base like Diatomaceous earth or kieselghar used as stationary phase in GLC. Inert gases like helium or nitrogen used as mobile phase(carrier gas) in both GSC and GLC.



which type of tablets does not require Disintegration test?
Ans) Sustained release tablets, Delayed released tablets and Chewable tablets.


What is disintegration time for Uncoated , coated, enteric coated, dispersible and soluble tablets?
Ans) Uncoated tablets – 30 min (Uses water as medium at 37+20C temperature)
Coated tablets- 30 min (Uses water as medium at 37+20C temperature)
Enteric Coated tablets- 60 min (Uses mixed phosphate buffer at 37+20C temperature) or It should no disintegration for 2 hours (Using in 0.1N Hcl as medium at 37+20C temperature)
Dispersible tablets – 3 min (Uses water as medium at 19 to 210C temperature)
Dispersible tablets – 3 min (Uses water as medium at 19 to 210C temperature)

What is disintegration time for soft gelatin and Hard gelatin capsules?

Ans)
Soft gelatin capsules- 60 min (Uses water as medium at 210C temperature)
Hard gelatin capsules – 30 min (Uses water as medium at 210C temperature)

Accuracy VS Precision:

Accuracy also known as trueness. Analytical Procedure accuracy is the closeness between the accepted reference value or conventional true value and the result value. One measurement is enough to determine the accuracy of an analytical procedure. It does not tell about the quality.
For accepted reference value is 20, you result value is 19.9 or 20.1. Then it is said as high accuracy.
In the same case, your result value is 18.7 0r 21.4. Then it is stated as low accuracy.
Precision: Analytical Procedure precision is the closeness between a number of measurements taken  from the homogenous sample multiple samplings under specified conditions. To measure the precision of an analytical procedure requires several measurements. It speaks about the quality.
For ex: From a homogenous sample, you have measured multiple samples, the values you obtain is
A. 19.2, 19.4, 19.3, 19.2, 19.1
B. 10.2, 10.4, 10.3, 10.2, 10.1
C. 19.2, 22.4, 16.6, 17.1, 16.9
In the above options, Result “A”& “B” said as High precision, Result “C” said as Low precision. Here the consideration is series of measurement values for a particular homogenous sample. There is no reference value in the concept of precision.

Differentiate between relative humidity and absolute humidity?

Ans) Absolute humidity also called as Humidity. Simply defined as amount of water vapour (moisture) present in a volume of air. Unit expressed as gram/m3.
“Relative” humidity: “Relative” nothing but comparison or ratio. So it is expressed in percentage(%). It is the ratio of air current water vapour/moisture/humidity to highest possible water vapour /moisture/ humidity. This highest possible humidity depends upon the current specific air temperature.
Ex: Current air contains 1 gram/m3 of water vapour (humidity), For that air it can hold up to 4 gram/m3 of water vapour (humidity) (It depends on temperature).
Relative humidity = ¼*100 = 25%
LOD:
Limit of Detection: Also known as Detection Limit. For a particular analytical procedure, Upto how much lowest amount of component or analyte  in a sample can be detected. That is the detection limit for that individual or particular analytical procedure. It does not mean that it should able to quantitate that analyte.  It should able to detect that analyte, that’s it.
  1. LOQ: Limit of Quantitation: Also known as Quantitation Limit. For a particular analytical procedure, up to how much lowest of analyte in sample can be quantitated with suitable accuracy and precision. LOQ come into picture in quantitative assays to determine the degraded products or impurities in the samples.